METRObility Optical Systems R115-26 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Matériel d'enregistrement METRObility Optical Systems R115-26. METRObility Optical Systems R115-26 User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Installation & User Guide
100Mbps Models: 2731-11/ 2731-13/ 2731-14/ 2731-15/ 2731-17/ 2731-1J
10Mbps Model: 2711-11
“redundant twister”
TM
MAIN PWR
AT
LK
A
B
PRIMARY
AT
LK
SECONDARY
AT
RESET
LKSW
“redundant twister”
2711
X
II
X
II
X
II
TM
MAIN PWR
AT
LK
A
B
PRIMARY
AT
LK
SECONDARY
AT
RESET
LKSW
“redundant twister”
2731
TM
MAIN PWR
AT
LK
A
B
AT
LK
AT
TX RX TX RX
RESET
LKSW
“redundant twister”
2731
10BASE-T
100BASE-TX
100BASE-TX/FX
TM
MAIN PWR
AT
LK
A
B
AT
LK
100BASE-TX/FX
AT
RESET
LKSW
“redundant twister”
2731
TX RX TX RX
TM
MAIN PWR
AT
LK
A
B
PRIMARY
AT
LK
SM (LH)
SECONDARY
100BASE-TX/FX
AT
RESET
LKSW
“redundant twister”
2731
TX RX TX RX
TM
MAIN PWR
AT
LK
A
B
PRIMARY
AT
LK
SECONDARY100BASE-TX/FX
AT
RESET
LKSW
“redundant twister”
2731
TX RX TX RX
SM (ELH)
SECONDARY
SECONDARY
SM (ELH)
PRIMARY
SM (LH)
PRIMARY
Vue de la page 0
1 2 3 4 5 6 ... 27 28

Résumé du contenu

Page 1 - “redundant twister”

Installation & User Guide100Mbps Models: 2731-11/ 2731-13/ 2731-14/ 2731-15/ 2731-17/ 2731-1J10Mbps Model: 2711-11“redundant twister”™TMMAIN PWRAT

Page 2

10 Installation Guide2711-11 Only: The 2711-11 provides two additional DIP switches whichare described in the following table.Switch Name Position Op

Page 3 - Table of Contents

Metrobility “redundant twister” 11Set the MDI-II/MDI-X Switches(2711-11 only)Next to each RJ-45 connector is a small push button switch used to i

Page 4

12 Installation GuideConnect to the NetworkA total of three connections must be made on the front panel whenconnecting the “redundant twister” media

Page 5 - Overview

Metrobility “redundant twister” 132731-XX 100BASE-TX connections:• When connecting a “redundant twister” 2731 to another device that isinternally

Page 6 - 6 Installation Guide

14 Installation GuideApply Power to the “redundant twister”Power is provided to the “redundant twister” from the desktop, universalinput, switching p

Page 7 - Installation Guide

Metrobility “redundant twister” 15Upon receiving power, the “redundant twister” goes into normal operationmode and automatically provides the app

Page 8 - Set the DIP Switches

16 Installation Guide

Page 9

Metrobility “redundant twister” 17User GuideThis section contains more detailed user information regarding the operatingfeatures of your “redunda

Page 10 - 10 Installation Guide

18 User GuideReset Push ButtonA small RESET push button is located on the front panel of the “redundant twister”.When used in conjunction with the un

Page 11 - Set the MDI-II/MDI-X Switches

Metrobility “redundant twister” 19ManagementStationManagementStationSwitch/Hubw/SNMPSwitch/Hubw/SNMP“redundant twister”2711“redundant twister”271

Page 12 - Connect to the Network

Metrobility “redundant twister”™Standalone Units10Mbps2711-11 ______ RJ-45 to redundant RJ-45100Mbps2731-11 ______ RJ-45 to redundant RJ-452731-13 ___

Page 13

20 User GuideBack-to-Back ApplicationA typical application of the “redundant twister” is to use them in pairs to extend anetwork’s reach between two

Page 14 - 14 Installation Guide

Metrobility “redundant twister” 21Topology SolutionsEnterprise Switch100Mbps SwitchSecondary Link ASecondary Link BPrimary Link APrimaryLink BM

Page 15

22 User GuideTechnical SpecificationsData Rate2711-11Half duplex _______________________________________________ 10MbpsFull duplex___________________

Page 16 - 16 Installation Guide

Metrobility “redundant twister” 23100Mbps Singlemode Fiber Optic Interface (2731-XX)Connector ___________________________________________________

Page 17 - User Guide

24 User GuideStraight RJ-45 Twisted-Pair CablesCrossover RJ-45 Twisted-Pair CablesDONOTUSEPATCHCABLECOLORBrownBrown StripeGreenBlue StripeBlueGreen S

Page 18 - Reset Push Button

Metrobility “redundant twister” 25Product Safety, EMC and Compliance StatementsThis equipment complies with the following requirements:•UL• CSA•

Page 19

26 User GuideWarranty and ServicingThree-Year Warranty for Metrobility “redundant twister”Metrobility Optical Systems, Inc. warrants that every “redu

Page 20 - Back-to-Back Application

Metrobility “redundant twister” 27

Page 21 - Topology Solutions

25 Manchester Street, Merrimack, NH 03054 USAtel: 1.603.880.1833 • fax: 1.603.594.2887www.metrobility.com5620-273100-001 H4/02

Page 22 - Technical Specifications

Table of Contents“redundant twister” Installation & User GuideOverview ...

Page 24 - 24 User Guide

Metrobility “redundant twister” 5OverviewThe Metrobility “redundant twister” offers the resiliency of data linkredundancy to ensure network integ

Page 25

6 Installation GuideThe “redundant twister” is available in several different models. These models eachcontain a MAIN port, a PRIMARY port and a SECO

Page 26 - Warranty and Servicing

Metrobility “redundant twister” 72Installation GuideFollow the simple steps outlined in this section of the guide to install and startusing your

Page 27

8 Installation GuideSet the DIP SwitchesA set of DIP switches, located on the back panel, provides user-selectableconfigurability options for several

Page 28 - 5620-273100-001 H

Metrobility “redundant twister” 92731-XX and 2711-11: The DIP switches are marked on the back paneland can be set for the following operational f

Commentaires sur ces manuels